Metrology & InspectionKLA 2139 family
Research Quality: 50% complete

The KLA 2139 is a brightfield inspection system. The KLA 2139 is used for semiconductor wafer inspection. The KLA 2139 supports 6-inch and 8-inch wafers.[1][2]

2139 Brightfield — Inventory photo
Fig. 012139 BrightfieldInventory photo[1]

What it is

General reference — not yet source-verified

Brightfield inspection tools illuminate the wafer from below and collect reflected light to create high-contrast images of surface features, enabling the detection of pattern defects, particles, and other anomalies.

How it works

General reference — not yet source-verified

Brightfield inspection relies on a microscope objective that directs light onto the wafer surface and captures the reflected light. The intensity of the reflected light varies with the topography and material properties of the wafer, producing an image that highlights deviations from the expected pattern.

The system scans the wafer in a step-and-repeat or continuous motion, capturing images at high magnification. An automated image processor compares each die image to a reference or to neighboring dice, flagging any differences that exceed a programmable threshold.

Where it fits in the process flow

General reference — not yet source-verified

In a semiconductor fab, brightfield inspection tools are part of the in-line metrology and inspection segment, providing feedback to process engineers for yield improvement and process control. The tool sits between the lithography track and subsequent deposition or etch equipment, or after any critical patterning step.

What do the numbers mean?

Power & electrical10

Voltage
208 VAC[1]
Accurate?
Phase
3 Phase[1]
Accurate?
50/60 Hz[1]
Accurate?
Voltage
208 V, 3 Phase[2]
Accurate?
Voltage
208 V[5]
Accurate?
50 / 60 Hz[5]
Accurate?
Frequency
50/60 Hz[1]
Accurate?
Electrical
208 VAC, 3 Phase, 30 A, 50/60 Hz[1]
Accurate?
Electrical
208 V, 3 Phase, Full load: 30A, 50/60 Hz[2]
Accurate?
Electrical
208 V, 50/60 Hz[5]
Accurate?

Wafer handling3

Wafer inspector software
Rev. V5.4.010[6]
Accurate?
Wafer sizes
6 inch, 8 inch[1]
Accurate?
Wafer Sizes
6, 8 inch[1]
Accurate?

Control & software1

Software
WIN NT[4]
Accurate?

Configuration & options11

30 A[1]
Accurate?
Full load
30A[2]
Accurate?
Parts Unit[5]
Accurate?
Power
60[5]
Accurate?
Windows NT Workstation[6]
Accurate?
Full Load Current
30 A[1]
Accurate?
Vintage
1996[1]
Accurate?
Current (full load)
30 A[1]
Accurate?
OEM
KLA[7]
Accurate?
Model
2139[7]
Accurate?
Type
Brightfield Inspection[7]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Voltage208 VAC[1]
  • Phase3 Phase[1]
  • Configuration50/60 Hz[1]
  • Voltage208 V, 3 Phase[2]
  • Voltage208 V[5]
  • Configuration50 / 60 Hz[5]
  • Frequency50/60 Hz[1]
  • Electrical208 VAC, 3 Phase, 30 A, 50/60 Hz[1]
  • Electrical208 V, 3 Phase, Full load: 30A, 50/60 Hz[2]
  • Electrical208 V, 50/60 Hz[5]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What wafer sizes does the KLA 2139 support?

The KLA 2139 supports 6-inch and 8-inch wafer sizes.[1][8]

Is the KLA 2139 a brightfield or darkfield inspection system?

The KLA 2139 is a brightfield inspection system.[7][1][2][5][8]

Not publicly documented

The following facts about the 2139 Brightfield are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 2139 Brightfield are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 2139 Brightfield are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 2139 Brightfield are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 2139 Brightfield are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 2139 Brightfield is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (8)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]Inventory photo
  3. [3]Inventory photo
  4. [4]Inventory photo
  5. [5]inventory listing
  6. [6]inventory listing
  7. [7]Equipment inventory listing
  8. [8]Equipment inventory listing
Was this page accurate?

Last updated Oct 10, 2026.

Compare with similar tools

View all →