Waferpedia

Applied Materials

Centura AP Enabler Dielectric

Centura AP Enabler Dielectric — Inventory photo
Fig. 01Centura AP Enabler DielectricInventory photo[1]

Wafer size

Diameter 300+/- 0.05mm(SEMI M28), 775 +/- 25um, Notch

Power

208V, 50/60Hz[1]

Vacuum

SMC pressure switch[1]

Gas delivery

C4F6 100 sccm UNIT IFC-125[4]

What is it?

Applied Materials Centura AP Enabler Dielectric Etcher is a 300 mm dielectric etcher with GEM/CIM JGJ online connection and a 3 carrier stage interface.

What do the numbers mean?

Power & electrical5

Voltage
208V, 50/60Hz[1]
Accurate?
RF Gen Top (162MHz Source)
3500W RF POWER SUPPLY, 162 MHZ, FIXED FREQUENCY, 208VAC, WATER COOLED (0190-29389)[4]
Accurate?
RF Gen #1 Bottom (13MHz Bias)
RF GENERATOR, 13MHZ 5KW, 300MM, RACK MOUNT (0190-15319)[4]
Accurate?
RF Gen #2 Bottom (2MHz Bias)
RF GEN PLASMA 9KW 2MHZ ENI (0190-29586)[4]
Accurate?
Chamber Controller Module
SBC C400MHZ, 3U CPCI, 256MB RAM[4]
Accurate?

Vacuum & pumping7

Facility Plate
N2 Regulator : Supplied by customer in floor, CDA regulator 125 PSI onboard[1]
Accurate?
SMC pressure switch[1]
Accurate?
Facility Plate
Pressure Gauge : Supplied by customer on regulator in floor[1]
Accurate?
Transfer Pressure Monitor
10 Torr Manometer and 1SLM N2 APC, kit[1]
Accurate?
Transfer Pressure Monitor
GAUGE VAC MINI-CONVECTRON W/1-SETPOINT CAJON FTG analog[1]
Accurate?
Load Lock Pressure Monitor
GAUGE VAC MINI-CONVECTRON W/1-SETPOINT CAJON FTG analog[1]
Accurate?
Dry Pump
N(ESR80WN (EBARA); customer Supply)[4]
Accurate?

Wafer handling9

Wafer Size
Diameter 300+/- 0.05mm(SEMI M28), 775 +/- 25um, Notch[1]
Accurate?
Inter Face
3 carrier stage (Continuous flow operation) w/ 3 Loadports (Semi compliant[1]
Accurate?
Loader Mod Corrosion Prevent
N/A[1]
Accurate?
Transfer Chamber Blade Kit
Transfer Chamber Accelerator Blade Kit[1]
Accurate?
Interface
3 carrier stage (Continuous flow operation) w/ 3 Loadports (Semi compliant[1]
Accurate?
Atmospheric Robot
KAWASAKI A3[1]
Accurate?
Mainframe Robot
VXP with Dual blade[1]
Accurate?
Loadport Type
Enhanced 25 wafer FOUP[1]
Accurate?
Wafer Pass Through
Not available[1]
Accurate?

Gas & chemistry14

Gas Line 1
C4F6 100 sccm UNIT IFC-125[4]
Accurate?
Gas Line 2
CH2F2 100 sccm UNIT IFC-125[4]
Accurate?
Gas Line 3
C3F8 50 sccm UNIT IFC-125[4]
Accurate?
Gas Line 4
O2_M 300 sccm UNIT-125[4]
Accurate?
Gas Line 5
SO2 200 sccm UNIT IFC-125[4]
Accurate?
Gas Line 6
CF4 200 sccm UNIT IFC-125[4]
Accurate?
Gas Line 7
C4F6_IGI 5 sccm UNIT-125[4]
Accurate?
Gas Line 8
O2_IGI 5 sccm UNIT-125[4]
Accurate?
Gas Line 9
O2_L 50 sccm UNIT-125[4]
Accurate?
Gas Line 10
O2_H 5000 sccm UNIT-125[4]
Accurate?
Gas Line 11
Ar 2000 sccm UNIT-125[4]
Accurate?
Gas Line 12
N2 200 sccm UNIT-125[4]
Accurate?
Gas Line 13
CHF3 200 sccm UNIT-125[4]
Accurate?
Gas Line 14
C4F8 100 sccm UNIT-125[4]
Accurate?

Control & software3

Online Connection
GEM / CIM JGJ (Hardware Interface : Ethernet 100Base-Tx)[1]
Accurate?
Interface A
Hardware related to EDA[1]
Accurate?
Fab Interface Type
Centura Etch 5.3 FAC. Frame 5.3 Fi Rev 002[4]
Accurate?

Configuration & options20

HDD not included[1]
Accurate?
MENV and FMS assemblies[1]
Accurate?
Corrosion Resistant FI & SWLL
N/A[1]
Accurate?
Standard SWLL
Standard SWLL[1]
Accurate?
Side Storage Pod
Side Storage Pod (Left/Right)[1]
Accurate?
OCR
KIT, YAT BACKSIDE OCR, 300MM 5.3FI[1]
Accurate?
Facility Plate
Manual Valve : Supplied by customer in floor[1]
Accurate?
LL ISO-Slit Valve Grp Elast.
AP Chemraz 513 Elastomer[1]
Accurate?
Loadports
Loadport System[1]
Accurate?
EMO Type
Turn to Release (Front x3, Rear x4) - 3 on FI, 1 on front of FI and one on each side of FI. Rear: 1 for each process chamber.[1]
Accurate?
System Monitors
Monitor #1 is Flat Panel with Keyboard on stand / Monitor #2 is through the wall flat panel (optional)[1]
Accurate?
Vintage
2010[1]
Accurate?
Description
Dielectric Etch[2]
Accurate?
Version
300mm[3]
Accurate?
Description
Dielectric Etch - Etch/Ash/Clean - Plasma Processing[3]
Accurate?
Process Chambers
4 process chambers[4]
Accurate?
Endpoint Type
Endpoint type (Eye-D) (0246-00196)[4]
Accurate?
TMP
Shimadzu D3403M, 3000 litre TMP[4]
Accurate?
Source Bottom Ring
QUARTZ RING SOURCE, E5 (0200-07362)[4]
Accurate?
Showerhead Assy
Showerhead Assy, 4mm SiC Top Electrode Tokai (0041-32335)[4]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
Centura AP Enabler E5—2010Dielectric Etcher with 4 process chambers; Fab Interface type: Centura Etch 5.3 FAC; Frame 5.3 Fi Rev 002fabsurplus.com[4]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Facility PlateN2 Regulator : Supplied by customer in floor, CDA regulator 125 PSI onboard[1]
  • ConfigurationSMC pressure switch[1]
  • Facility PlatePressure Gauge : Supplied by customer on regulator in floor[1]
  • Transfer Pressure Monitor10 Torr Manometer and 1SLM N2 APC, kit[1]
  • Transfer Pressure MonitorGAUGE VAC MINI-CONVECTRON W/1-SETPOINT CAJON FTG analog[1]
  • Load Lock Pressure MonitorGAUGE VAC MINI-CONVECTRON W/1-SETPOINT CAJON FTG analog[1]
  • Voltage208V, 50/60Hz[1]
  • RF Gen Top (162MHz Source)3500W RF POWER SUPPLY, 162 MHZ, FIXED FREQUENCY, 208VAC, WATER COOLED (0190-29389)[4]
  • RF Gen #1 Bottom (13MHz Bias)RF GENERATOR, 13MHZ 5KW, 300MM, RACK MOUNT (0190-15319)[4]
  • RF Gen #2 Bottom (2MHz Bias)RF GEN PLASMA 9KW 2MHZ ENI (0190-29586)[4]
  • Dry PumpN(ESR80WN (EBARA); customer Supply)[4]
  • Chamber Controller ModuleSBC C400MHZ, 3U CPCI, 256MB RAM[4]
  • Gas Line 1C4F6 100 sccm UNIT IFC-125[4]
  • Gas Line 2CH2F2 100 sccm UNIT IFC-125[4]
  • Gas Line 3C3F8 50 sccm UNIT IFC-125[4]
  • Gas Line 4O2_M 300 sccm UNIT-125[4]
  • Gas Line 5SO2 200 sccm UNIT IFC-125[4]
  • Gas Line 6CF4 200 sccm UNIT IFC-125[4]
  • Gas Line 7C4F6_IGI 5 sccm UNIT-125[4]
  • Gas Line 8O2_IGI 5 sccm UNIT-125[4]
  • Gas Line 9O2_L 50 sccm UNIT-125[4]
  • Gas Line 10O2_H 5000 sccm UNIT-125[4]
  • Gas Line 11Ar 2000 sccm UNIT-125[4]
  • Gas Line 12N2 200 sccm UNIT-125[4]
  • Gas Line 13CHF3 200 sccm UNIT-125[4]
  • Gas Line 14C4F8 100 sccm UNIT-125[4]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the Centura AP Enabler Dielectric are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Centura AP Enabler Dielectric are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the Centura AP Enabler Dielectric are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Centura AP Enabler Dielectric are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Centura AP Enabler Dielectric is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Centura AP Enabler Dielectric are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]fabsurplus.comfabsurplus.com
  3. [3]fabsurplus.comfabsurplus.com
  4. [4]fabsurplus.com — fabsurplus.comfabsurplus.com
Was this page accurate?

Last updated Oct 6, 2026.

Compare with similar tools