Power

2 mV/div to 5 V/div in 1-2-5 sequence[1]

Performance

±3%[1]

What it is

The Tektronix 2213 A is an oscilloscope.[2]

How it works

The 2213A uses a display, vertical controls, horizontal controls, and trigger controls to present waveforms and support time and voltage measurements.[1]

Applications

The 2213A supports voltage measurements, time measurements, television displays, and delayed-sweep magnification.[1]

The 2213A includes probe compensation, common-mode rejection, rise-time measurement, and phase-difference measurement procedures.[1]

What do the numbers mean?

Power & electrical6

Bandwidth (-3 dB)
DC to at least 60 MHz (5 mV/div to 5 V/div); DC to at least 50 MHz (2 mV/div)[1]
Accurate?
Deflection factor range
2 mV/div to 5 V/div in 1-2-5 sequence[1]
Accurate?
Rise time
≤5.8 ns (5 mV/div to 5 V/div, 0°C to +35°C); ≤7.0 ns (2 mV/div to 5 V/div, 0°C to +50°C)[1]
Accurate?
Maximum safe input voltage
400 V (dc + peak ac) or 800 V ac p-p to 10 kHz[1]
Accurate?
Common-mode rejection ratio
≥20:1 at 25 MHz[1]
Accurate?
Channel isolation
>100:1 at 25 MHz[1]
Accurate?

Performance1

Accuracy
±3%[1]
Accurate?

Control & software1

CRT size
80 x 100 mm[1]
Accurate?

Configuration & options4

Channels
Dual[1]
Accurate?
Sweep speed range
0.5 s/div to 50 ns/div (calibrated); X10 magnifier extends to 5 ns/div[1]
Accurate?
Input resistance
1 MΩ ±2%[1]
Accurate?
Input capacitance
20 pF ±2 pF[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Bandwidth (-3 dB)DC to at least 60 MHz (5 mV/div to 5 V/div); DC to at least 50 MHz (2 mV/div)[1]
  • Deflection factor range2 mV/div to 5 V/div in 1-2-5 sequence[1]
  • Rise time≤5.8 ns (5 mV/div to 5 V/div, 0°C to +35°C); ≤7.0 ns (2 mV/div to 5 V/div, 0°C to +50°C)[1]
  • Maximum safe input voltage400 V (dc + peak ac) or 800 V ac p-p to 10 kHz[1]
  • Common-mode rejection ratio≥20:1 at 25 MHz[1]
  • Channel isolation>100:1 at 25 MHz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What instrument is the Tektronix 2213 A?

The Tektronix 2213 A is an oscilloscope.[2]

Not publicly documented

The following facts about the 2213 A Oscilloscope are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 2213 A Oscilloscope are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 2213 A Oscilloscope are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 2213 A Oscilloscope are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 2213 A Oscilloscope are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 2213 A Oscilloscope is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]w140.com — w140.comw140.com
  2. [2]Equipment inventory listing
Was this page accurate?

Last updated Oct 8, 2026.

Compare with similar tools

View all →