Waferpedia

Perkin Elmer

11 067 Ion Gun Control

Perkin Elmer 11 067 Ion Gun Control family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Perkin Elmer 11 067 Ion Gun Control is a sputter ion gun control unit from the Physical Electronics Division of Perkin-Elmer. The Perkin Elmer 11 067 Ion Gun Control provides a beam voltage adjustable from zero to +5000 volts DC. The Perkin Elmer 11 067 Ion Gun Control has a pressure range of 0-50 mP.[1]

11 067 Ion Gun Control — Inventory photo
Fig. 0111 067 Ion Gun ControlInventory photo[2]

Power

0 to +5000 volts DC[1]

Vacuum

0-50 mP[1]

How it works

The 11 067 control uses a feedback loop where the emission current from the filament is measured and used to regulate the filament current supply, keeping the emission constant. The two-axis deflection system generates push-pull triangular output voltage waveforms for both X and Y axes, with amplitudes adjustable between 0 and +200 volts AC peak-to-peak and a DC level of 110 volts. A special electrically isolated aperture plate in the ion gun collects a fraction of the electrons produced in the ionization region; this current is a function of pressure and is read as a pressure signal on the panel meter.[1]

The control includes a three-position toggle switch for beam voltage (ON, OFF, or REMOTE via TTL signal). A five-turn digital readout control sets the beam voltage, and another five-turn control sets the focus voltage ratio. Raster amplitude is controlled by single-turn potentiometers for each axis, with a master toggle to enable or disable the deflection system. The emission current or pressure can be selected for display on the panel meter via a two-position switch.[1]

What do the numbers mean?

Power & electrical5

Beam voltage range
0 to +5000 volts DC[1]
Accurate?
Focus ratio
70-100% of beam voltage[1]
Accurate?
Minimum focus voltage
100 volts DC[1]
Accurate?
Raster amplitude
0 to +200 volts peak-to-peak[1]
Accurate?
Ripple
0.2 V peak-to-peak[1]
Accurate?

Vacuum & pumping1

Pressure range
0-50 mP[1]
Accurate?

Configuration & options3

Anode current
25 uA at 50 mP[1]
Accurate?
Output current
50 mA[1]
Accurate?
Stability
1% per hour[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Beam voltage range0 to +5000 volts DC[1]
  • Focus ratio70-100% of beam voltage[1]
  • Minimum focus voltage100 volts DC[1]
  • Raster amplitude0 to +200 volts peak-to-peak[1]
  • Pressure range0-50 mP[1]
  • Ripple0.2 V peak-to-peak[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the beam voltage range of the 11 067 ion gun control?

The beam voltage power supply can be adjusted to any value between zero and +5000 volts DC.[1]

How is the focus voltage adjusted?

The focus voltage is set as a ratio of the beam voltage, variable between 70 and 100 percent, with a minimum of 100 volts DC.[1]

What is the raster amplitude range for the deflection system?

The raster amplitude for each axis is adjustable between 0 and +200 volts peak-to-peak.[1]

What pressure range does the pressure measurement circuit cover?

The pressure range is 0 to 50 mP (millipascal).[1]

What is the stability specification of the 11 067 control?

The stability is 1% per hour, with ripple of 0.2 V peak-to-peak.[1]

What is the output current capability of the control?

The output current is 50 mA.[1]

Not publicly documented

The following facts about the 11 067 Ion Gun Control are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 11 067 Ion Gun Control are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 11 067 Ion Gun Control are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 11 067 Ion Gun Control are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 11 067 Ion Gun Control are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 11 067 Ion Gun Control is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]engineering.purdue.edu — engineering.purdue.eduengineering.purdue.edu
  2. [2]Inventory photo
Was this page accurate?

Last updated Sep 24, 2026.

Compare with similar tools