The KLA Quantox is a non-contact, corona-based silicon and oxide charge monitoring system. The Quantox system measures electrical characteristics such as charge composition, interface quality, dielectric thickness, and charge contamination of semiconductors and dielectric films.[1]

KLAQuantox
No photo available yet

Performance

0.10 Å[2]

Optics

130 nm and below[2]

What it is

The KLA Quantox is a semiconductor metrology and inspection system for monitoring oxide and dielectric film behavior on wafers.[2][1][4]

The Quantox family includes Quantox 64000 Monitoring and Quantox 64100 Measurement.[3]

How it works

The Quantox system is a non-contact, corona-based silicon and oxide charge monitoring system.[1]

The Quantox system uses measurement principles similar to MOS C-V testing, but the probe does not touch the wafer surface.[1]

Where it fits in the process flow

The Quantox system measures wafers after gate formation to assess gate dielectric quality and reliability.[1][2]

Applications

The Quantox system measures charge composition, interface quality, dielectric thickness, and charge contamination in semiconductors and dielectric films.[1]

The Quantox system can monitor metallic contamination such as Fe, Al, Cu, and Na.[1]

What do the numbers mean?

Power & electrical1

CE compliance
Compliant with EC Machinery, Low Voltage, and EMC directives[1]
Accurate?

Wafer handling1

Wafer sizes supported
200 mm, 300 mm[1]
Accurate?

Optics & imaging1

Technology node
130 nm and below[2]
Accurate?

Performance1

Accuracy
0.10 Å[2]
Accurate?

Control & software3

Measured parameters
Charge composition, interface quality, dielectric thickness, charge contamination[1]
Accurate?
Operating system
Windows NT[1]
Accurate?
Interface
SECS/GEM[1]
Accurate?

Configuration & options5

Measurement principle
Non-contact, corona-based[1]
Accurate?
Metallic contamination detection
Fe, Al, Cu, Na[1]
Accurate?
Gate dielectric materials
SiON, high-k[2]
Accurate?
Correlation with device parameters
>95%[2]
Accurate?
Technology
ACTIV[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
Quantox XP—2002Next-generation non-contact in-line electrical characterization system for 130 nm and below; uses ACTIV technology; accuracy within 0.10 Å; correlation >95% with device parameters.kla.com[2]
Quantox 64000——Monitoring model listed in Waferpedia.waferpedia.com[3]
Quantox 64100——Measurement model listed in Waferpedia.waferpedia.com[3]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • CE complianceCompliant with EC Machinery, Low Voltage, and EMC directives[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of measurement system is the Quantox?

The Quantox is a non-contact, corona-based silicon and oxide charge monitoring system.[1][3]

What does the Quantox measure?

The Quantox measures charge composition, interface quality, dielectric thickness, and charge contamination of semiconductors and dielectric films.[1][3]

What process events can the Quantox help detect early?

The Quantox can support early detection of contamination and plasma damage events.[1]

Not publicly documented

The following facts about the Quantox are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Quantox are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the Quantox are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Quantox are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Quantox is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Quantox are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]photonicmicrodevices.com — photonicmicrodevices.comphotonicmicrodevices.com
  2. [2]kla.com — kla.comkla.com
  3. [3]waferpedia.com — waferpedia.comwaferpedia.com
  4. [4]Equipment inventory listing
Was this page accurate?

Last updated Sep 29, 2026.

Compare with similar tools

View all →