Espec
The Espec EHS-412MD is a large highly accelerated stress test system. The Espec EHS-412MD has an interior size of φ294×L318 mm ×2stage. The Espec EHS-412MD operates over +105.0°C to +162.2°C, 75%rh to 100%rh, and 0.019 to 0.389 MPa (gauge).[1]
Process applications and technology nodes documented for this tool.
| Designation | Generation | Vintage | Changes | Source |
|---|---|---|---|---|
| EHS-412(M) | — | — | Listed as the related single-stage model in the same lineup; the EHS-412MD is the two-stage version with the same stated temperature, humidity, and pressure range. | espec.co.jp[1] |
| EHS-432(M) | — | — | Listed in the larger-size highly accelerated stress test system lineup. | espec.co.jp[1] |
| EHS-212(M) | — | — | Listed in the standard highly accelerated stress test system lineup. | espec.co.jp[1] |
| EHS-222(M) | — | — | Listed in the standard highly accelerated stress test system lineup. | espec.co.jp[1] |
| EHS-212MD | — | — | Two-stage variant with 294 x 318 mm interior dimensions. | espec.co.jp[1] |
| EHS-222MD | — | — | Two-stage variant with 394 x 426 mm interior dimensions. | espec.co.jp[1] |
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
Each chamber has an interior volume of 21 liters (0.64 cubic feet).[2][3]
The EHS-412MD fully conforms to EIA/JEDEC test methods A110 and 102C.[2]
The pressure range is 0.02 to 0.392 megapascals gauge (0 to 57 psig).[2]
Yes, the EHS-412MD includes specimen power terminals that allow power-up of specimens during test.[2]
The following facts about the EHS-412MD are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the EHS-412MD are on record.
Answerable by: OEM historical records or a trade-press announcement
The control-system platform and OS era of the EHS-412MD are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the EHS-412MD are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the EHS-412MD is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the EHS-412MD are on record.
Answerable by: an OEM parts catalog or a service engineer
No research found yet — worked with this tool? Share what you know.