PD 03 Helium Leak Detector

Metrology & InspectionAgilent PD 03 family
Research Quality: 50% complete
PD 03 Helium Leak Detector — Inventory photo
Fig. 01PD 03 Helium Leak DetectorInventory photo[1]

Power

100-120 or 200-230 V, 50/60 Hz[3]

Vacuum

Dry scroll pump[2]

What it is

The Agilent PD 03 is a portable dry helium leak detector manufactured by Agilent Technologies (originally developed as the Varian PD 03).[2]

The PD 03 is a helium mass spectrometer leak detector designed to locate and measure very small leaks in enclosed systems or devices.[2]

The instrument uses an oil-free scroll/diaphragm combination pump with a pumping speed of 3 m³/h.[2]

A variant of the PD 03, carrying Agilent part number G8610B, includes an internal oil-free IDP-3 dry scroll vacuum pump with a pumping speed of 3.6 m³/h.[3]

How it works

The instrument features a large color touch screen with 180° rotation and an intuitive interface that provides six pre-programmed application setups: Sniffing, Spray Method, High Sensitivity, Auto Sequencer, PPM Testing, and Split Flow.[2]

The PD 03 achieves a minimum detectable leak rate of ≤ 5·10⁻¹² mbar·l/s in vacuum mode and has a helium pumping speed of 1.8 l/s.[2]

The unit includes a built-in turbo primary pump, RS232 and analog interfaces as standard, and optional discrete I/O and a wireless handheld remote with a 100-meter range.[2]

Where it fits in the process flow

In semiconductor manufacturing, the PD 03 is used to verify the integrity of vacuum systems in process tools, gas panels, and gas transfer lines, ensuring that leaks do not compromise process quality or safety.[2]

Applications

The PD 03 is applied in semiconductor production, scientific research, electron microscopes, experimental chambers, surface analytical systems, space chambers, power generation condensers, heat exchangers, steam circuits, automotive components, electrical and refrigeration systems, hermetic packaging, medical implantable devices, and industrial process tools such as vacuum furnaces, electron beam welding, and coating systems.[2]

What do the numbers mean?

Power & electrical1

Operating voltage
100-120 or 200-230 V, 50/60 Hz[3]
Accurate?

Vacuum & pumping8

Refurbished in 2019, replaced an oil fore pump with a Teflon scroll pump[1]
Accurate?
The turbo to achieve high vacuum fails, needs replacing[1]
Accurate?
Primary pump type
Dry scroll pump[2]
Accurate?
Pumping speed
3 m³/hr[2]
Accurate?
Pumping speed
3.6 m³/h (3 CFM)[3]
Accurate?
Minimum detectable leak rate
≤ 5·10⁻¹² mbar·l/s[2]
Accurate?
Maximum inlet pressure
13 mbar[2]
Accurate?
Helium pumping speed
1.8 l/s[2]
Accurate?

Control & software2

Interface
RS232 and analog (standard), discrete IO (optional)[2]
Accurate?
Remote control range
100 meters[2]
Accurate?

Dimensions & facilities1

Dimensions (W x H x D)
625 x 403 x 517 mm[2]
Accurate?

Configuration & options10

Includes adapters (1/8" to 1.118")[1]
Accurate?
Issues:[1]
Accurate?
A calibrated leak requires updating[1]
Accurate?
Measurement ranges
12 decades[2]
Accurate?
Time until ready
≤ 2 min[2]
Accurate?
Response time
< 0.5 sec[2]
Accurate?
Display
8.4 inch color TFT touch screen[3]
Accurate?
Languages
Chinese, English, French, German, Japanese, Korean, Russian, Spanish[3]
Accurate?
Conforms to
CE, UL, CSA standards[2]
Accurate?
Application setups
Six pre-programmed key applications[3]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
HLD PD03——Portable dry leak detection unit with built-in application setups, touch screen interface, and oil-free scroll/diaphragm pump combination.heliumleakdetection.net[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationRefurbished in 2019, replaced an oil fore pump with a Teflon scroll pump[1]
  • ConfigurationThe turbo to achieve high vacuum fails, needs replacing[1]
  • Primary pump typeDry scroll pump[2]
  • Pumping speed3 m³/hr[2]
  • Pumping speed3.6 m³/h (3 CFM)[3]
  • Minimum detectable leak rate≤ 5·10⁻¹² mbar·l/s[2]
  • Maximum inlet pressure13 mbar[2]
  • Helium pumping speed1.8 l/s[2]
  • Operating voltage100-120 or 200-230 V, 50/60 Hz[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the minimum detectable leak rate of the Agilent PD 03?

The minimum detectable leak rate is ≤ 5·10⁻¹² mbar·l/s in vacuum mode.[2]

What type of vacuum pump does the PD 03 use?

The PD 03 uses an oil-free scroll/diaphragm combination pump as standard; the G8610B variant uses an oil-free IDP-3 dry scroll vacuum pump.[2][3]

What is the pumping speed of the PD 03?

The standard PD 03 has a pumping speed of 3 m³/h; the G8610B variant has a pumping speed of 3.6 m³/h.[2][3]

What are the primary test methods available on the PD 03?

The PD 03 includes six pre-programmed application setups: Sniffing, Spray Method, High Sensitivity, Auto Sequencer, PPM Testing, and Split Flow.[2]

Not publicly documented

The following facts about the PD 03 Helium Leak Detector are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the PD 03 Helium Leak Detector are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the PD 03 Helium Leak Detector are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the PD 03 Helium Leak Detector are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the PD 03 Helium Leak Detector is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the PD 03 Helium Leak Detector are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]heliumleakdetection.net — heliumleakdetection.netheliumleakdetection.net
  3. [3]idealvac.com — idealvac.comidealvac.com
Was this page accurate?

Last updated Sep 27, 2026.

Compare with similar tools

View all →