The Agilent / Varian 7500 A is an inductively coupled plasma mass spectrometer (ICP-MS). The Agilent / Varian 7500 A uses a digital drive 27 MHz ICP RF generator and hyperbolic profile quadrupole rods.[1]

7500 A ICP-MS — Inventory photo
Fig. 017500 A ICP-MSInventory photo[1]

What it is

The Agilent 7500 A is an inductively coupled plasma mass spectrometer (ICP-MS) designed for trace element analysis.[1]

How it works

The Agilent 7500 A ICP-MS uses a Peltier-cooled spray chamber to introduce liquid samples into the plasma.[1]

The instrument features a fully automatic, computer-controlled torch position in all three axes and a ShieldTorch System (STS).[1]

The mass analyzer uses hyperbolic profile quadrupole rods driven by a highest-frequency, digitally synthesized 3 MHz RF Quadrupole Driver.[1]

Detection is performed by a simultaneous dual mode detector with an exclusive high-speed amplifier.[1]

Where it fits in the process flow

General reference — not yet source-verified

In semiconductor manufacturing, ICP-MS instruments are used for trace metal analysis to monitor contamination in process chemicals, deionized water, and on wafer surfaces.

What do the numbers mean?

Power & electrical4

High efficiency digital drive 27 MHz ICP RF generator[1]
Accurate?
Highest frequency, digitally synthesized 3 MHz RF Quadrupole Driver[1]
Accurate?
RF generator frequency
27 MHz[1]
Accurate?
RF Quadrupole Driver frequency
3 MHz[1]
Accurate?

Gas & chemistry1

Agilent Active Mass Flow Controllers (AMFC)[1]
Accurate?

Optics & imaging2

Simultaneous dual mode detector with exclusive high-speed amplifier[1]
Accurate?
Detector type
Simultaneous dual mode with high-speed amplifier[1]
Accurate?

Control & software2

Fully automatic, computer controlled torch position in all three axes[1]
Accurate?
Torch position control
Fully automatic, computer controlled in all three axes[1]
Accurate?

Configuration & options8

Peltier-cooled spray chamber[1]
Accurate?
ShieldTorch System (STS)[1]
Accurate?
Hyperbolic profile quadrupole rods[1]
Accurate?
7500 ICP-MSChemstationVer. B.02.01[1]
Accurate?
I-AS Integrated Autosampler for ICP-MS[1]
Accurate?
Brother Printer HL1440[1]
Accurate?
P 9621 D HP Flat Panel Monitor L1702 2Tone TCO99[1]
Accurate?
Spray chamber cooling
Peltier-cooled[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationAgilent Active Mass Flow Controllers (AMFC)[1]
  • ConfigurationHigh efficiency digital drive 27 MHz ICP RF generator[1]
  • ConfigurationHighest frequency, digitally synthesized 3 MHz RF Quadrupole Driver[1]
  • RF generator frequency27 MHz[1]
  • RF Quadrupole Driver frequency3 MHz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the 7500 A ICP-MS are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 7500 A ICP-MS are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 7500 A ICP-MS are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 7500 A ICP-MS are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 7500 A ICP-MS are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 7500 A ICP-MS is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.