Attribute
100 ICP FluorineOxford Instruments
OEMOxford InstrumentsSPTS
CategoryEtchEtch
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyOxford Instruments 100 ICP FluorineSPTS MACS ICP
Cited variants—
Specifications
Etch GasesSF6, CF4, O2, Ar, N2, CHF3, C4F8[2]—
Cryo DRIE etch rateup to 5 µm/min[2]—
Wafer size4 inch, 6 inch, 8 inch (with clamp change)[2]8 inch[3]
Configuration—HR chamber[3]
Clamp type—standard WTC[3]
Coil RF power—Advanced Energy RFG3001, 3kw[3]
Platen RF power—ENI ACG-3B 13.56MHZ, 300w[3]
Load lock pump—Ebara AAL10[3]
Chamber pump—Ebara A30W[3]
Turbo pump—Leybold MAG2000CT[3]
Turbo Pump Controller—Leybold MAG Drive 2000[3]
Chiller—ATS/DEX-20ADI[3]
Manufacturer—SPTS / STS[3]
Model—MACS ICP[3]
Category—Etch[4]
Chamber—HR chamber[3]
Wafer capability—6", 8" capable[3]
Wafer handling—MACS loader for cassette to cassette operation (2 load stations)[3]
Vacuum load lock—Carousel vacuum load lock[3]
Backside cooling—Helium backside cooling (HBC)[3]
Gases—C4F8 (200 sccm); SF6 (1000 sccm); O2 (200 sccm); Ar (50 sccm)[3]
Vintage—2002[3]
Voltage—208 Volts / 60 Hz, 40 Amps/phase[1]
Chamber quantity—1 chamber[5]

Plan your fab

Building a Etch process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]hommer.com.twhommer.com.tw
  2. [2]nanofab.utah.edunanofab.utah.edu
  3. [3]inventory listing
  4. [4]waferpedia.comwaferpedia.com
  5. [5]challentech.com.twchallentech.com.tw