0010-22161 High EFF RF MatchversusMPA 600 FA

Applied Materials 0010-22161 High EFF RF Match, Canon MPA 600 FA, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMApplied MaterialsCanon
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyApplied Materials 0010-22161 High EFF RF MatchCanon MPA 600
Specifications
MakeApplied Materials[1]—
Model0010-22161[1]—
DescriptionHTESC PH 1 REV A[2]—
ConditionUsed[2]—
Stock NumberBM6628[2]—
Configuration—Upgraded to 150 mm compatibility[3]
Type—1X mirror projection auto feeder / mask aligner[4]
Auto feeder—Single or double, cassette to cassette, backside wafer handling[4]
Wafer sizes—4 inch, 5 inch, 6 inch[4]
Mask sizes—5 inch, 6 inch, 7 inch[4]
Resolution—1.5 um (using positive resist)[4]
Illumination—2 kW high pressure mercury lamp[4]
Wavelengths used—365 nm (i-line), 405 nm (h-line), 436 nm (g-line)[4]
Intensity—At 1800 watts power output: 4 inch wafer more than 700 mW, 5 inch wafer more than 650 mW, 6 inch wafer more than 600 mW[4]
Intensity / exposure uniformity—Within plus/minus 3%[4]
Constant temperature control—Monitors and controls system temperature within plus/minus 0.3 degrees C[4]
Distortion control—PDC matic distortion control[4]
Automatic alignment—HeNe 633 nm laser beam scanning alignment[4]
Alignment modes—Spot beam / sheet beam[4]
Alignment accuracy—3sigma <= 0.54 um[4]
Required facilities—200 VAC, 3Phase, 6 kVA, 50/60Hz; Air Supply(CTC): 200 VAC, 3Phase, 8 kVA, 50/60Hz; CDA pressure minimum 6.5 kg/cm2, flow rate 130 lit/min; Vacuum 50 cmHg or more; Exhaust flow for illuminator 6.5 m/sec to 9.5 m/sec[4]
Compatibility upgrade—Upgraded to 150 mm compatibility[5]
Monitor—Monitor not included[5]
Vintage—1991 vintage[5]
Wafer handling—Single or double, cassette to cassette, backside wafer handling[5]
Tool type—1X mirror projection mask aligner[5]
Temperature control—Monitors and controls system temperature within plus/minus 0.3 degrees C[5]
Power / electrical—200 VAC, 3Phase, 6 kVA, 50/60Hz[5]
Air supply (CTC)—200 VAC, 3Phase, 8 kVA, 50/60Hz[5]
CDA pressure—Minimum 6.5 kg/cm2, flow rate 130 lit/min[5]
Vacuum—50 cmHg or more[5]
Exhaust flow for illuminator—6.5 m/sec to 9.5 m/sec[5]