0010-21246 PartversusScientific FEI Helios NanoLab 600 FIB

Applied Materials 0010-21246 Part, Thermo Fisher Scientific FEI Helios NanoLab 600 FIB, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
0010-21246 PartApplied Materials
OEMApplied MaterialsThermo Fisher
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
Family—Thermo Fisher Scientific FEI Helios NanoLab 600 FIB
Specifications
Configuration—Dual beam[1]
Sample stage—5-Axes motorized X-Y-Z-rotate-tilt stage[1]
Step size—100 nm (Minimum)[1]
High vacuum—10^-10 mbar[1]
X, Y-Axis—150 mm[1]
Z-Axis—10 mm[1]
Tilt range—-5° to +60°[1]
Source—SCHOTTKY Field emitter[1]
Accelerating voltage—350 V to 30 kV (Continuously adjustable)[1]
Beam current—1 pA - 22 nA[1]
Type—Dual beam[1]
Vacuum system—Edwards XDS10 Scroll pump[1]
Travel X, Y-Axis—150 mm[1]
Travel Z-Axis—10 mm[1]
Repeatability—1 µm at 0°; 2 µ at 52°[1]
Electron source—SCHOTTKY Field emitter[1]
Electron accelerating voltage—350 V to 30 kV (Continuously adjustable)[1]
Electron beam current—1 pA - 22 nA[1]
Electron resolution—0.9 nm at 15 kV; 1.4 nm at 1 kV[1]
Ion source—Liquid Gallium ion emitter[1]
Ion optics—Sidewinder Field emission focused ion beam optics[1]
Ion accelerating voltage—0.5 kV to 30 kV (Continuously adjustable)[1]
Ion beam current—1.5 pA - 20 nA[1]
Ion imaging resolution—5 nm at 30 kV[1]
Ion milling resolution—10 nn on Cr thin film[1]
Scanner resolutions—512x442, 1024x884, 2048x1768, 4096x3536 pixels[1]
Minimum dwell time—25 ns/pixel[1]
Patterning maximum resolution—64k x 64k[1]
Patterning maximum dwell—25 ms/pixel[1]
Detectors—In-lens SE and BSE True Lens Detector (TLD); Everhart-Thornely SE Detector (ETD); 14-Segments solid state STEM II detector; Chamber viewing IR CCD camera[1]
Controller—Microscope controller; LCD Monitor, 19"; Screen resolution 1280x1024; Optical mouse; Chamber door mounted interface for manipulators[1]
Imaging resolution—5 nm at 30 kV[1]
Milling resolution—10 nn on Cr thin film[1]
Resolution—512x442, 1024x884, 2048x1768, 4096x3536 pixels[1]
Maximum resolution—64k x 64k[1]
Minimum dwell—25 ns/pixel[1]
Maximum dwell—25 ms/pixel[1]
Screen resolution—1280x1024[1]
Instrument type—Dual beam focused ion beam (FIB)[1]
Stage—5-axis motorized X-Y-Z-rotate-tilt stage[1]
Stage travel X/Y—150 mm[3]
Stage travel Z—10 mm[1]
Vacuum pump—Edwards XDS10 scroll pump[1]
Sample stage step size—100 nm minimum[1]
Maximum dwell time—25 ms/pixel[1]
Additional included item—Broad beam plasma source ion column (focus 250 µm)[1]
Included documentation—Manuals included[1]
Manipulator—Does not include manipulator[1]
Stage control—5 axes motorized XYZRT 6 in UHR stage with piezo control[3]
Magnification—69x to 2,300,000x[3]
Detector—Through-lens detection for SE and BSE[3]
STEM detector—Retractable[3]
Stage tilt—-10° to +60°[3]
Optional accessories—Omniprobe Autoprobe 200; Ibss Group GV10x plasma cleaner[3]