-407B-2-S-CE-S293 RobotversusF 40 Thin Film Thickness Measurement

ABM -407B-2-S-CE-S293 Robot, KLA F 40 Thin Film Thickness Measurement, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMABMKLA
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-2-S-CE-S293 RobotKLA F 40 Thin Film Thickness Measurement
Cited variants—
Specifications
ModelABM-407B-2-S-CE-S293[2]—
DescriptionROBOT[2]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[2]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[2]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[2]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[2]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[2]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[2]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[2]—
Spectrometer Wavelength Range (F40)—400 – 850 nm[1]
Spectrometer Wavelength Range (F40-UV)—190 – 1100 nm[1]
Spectrometer Wavelength Range (F40-EXR)—400 – 1700 nm[1]
Spectrometer Wavelength Range (F40-NIR)—950 – 1700 nm[1]
Spectrometer Wavelength Range (F40-UVX)—190 – 1700 nm[1]
Spectrometer Wavelength Range (F40-XT)—1440 – 1690 nm[1]
Thickness Range (F40, 10X Objective)—20 nm – 45 µm[1]
Thickness Range (F40-UV, 10X Objective)—4 nm – 35 µm[1]
Thickness Range (F40-EXR, 10X Objective)—20 nm – 115 µm[1]
Thickness Range (F40-XT, 10X Objective)—0.2 µm – 140 µm[1]
Spot Size (50X Objective with 50µm Aperture)—1 µm[1]
Accuracy (F40, F40-EXR)—2 nm or 0.2%[1]
Accuracy (F40-UV, F40-UVX)—1 nm or 0.2%[1]
Precision (F40, F40-UV, F40-EXR, F40-UVX)—0.02 nm[1]
Power—100-240 VAC, 50-60 Hz, 20 W[1]
Measurement principle—Spectral reflectance[3]
Spot size (minimum)—1 µm[3]
Light source—Supplied by microscope[1]
Power requirements—100-240VAC, 50-60Hz, 20W[1]
Accuracy—The greater of 1nm or 0.2% (for F40-UV/-UVX); 2nm or 0.2% (for F40/-EXR); 3nm or 0.4% (for F40-NIR); 5nm or 0.4% (for F40-XT)[1]
Precision (1σ, 100 measurements of 1µm SiO2-on-Si)—0.02nm (F40-UV/-UVX/F40/-EXR); 0.1nm (F40-NIR); 1nm (F40-XT)[1]
Stability (2σ of daily average over 20 days)—0.05nm (F40-UV/-UVX/F40/-EXR); 0.12nm (F40-NIR); 1nm (F40-XT)[1]
Computer interface—USB 2.0[1]
Operating system (PC)—Windows 10 (64-bit) or later; macOS Catalina or later with Parallels[1]
Processor minimum—1.4 GHz[1]
Thickness range (F40 with 10X objective)—20nm – 45µm[1]
Wavelength range (F40)—400 – 850nm[3]